Data Centre Solutions and Consultancy

Data centre is a facility used to house computer systems and associated components, such as telecommunications and storage systems. It generally includes redundant or backup power supplies, redundant data communications connections, environmental controls (e.g., air conditioning, fire suppression) and security devices.

Now data center design, construction, and operation is a well-known discipline. Standard Documents from accredited professional groups, such as the Telecommunications Industry Association, specify the requirements for data center design. Well-known operational metrics for data center availability can be used to evaluate the business impact of a disruption. There is still a lot of development being done in operation practice, and also in environmentally friendly data center design. Data centers are typically expensive to build and maintain.

 

 

IT operations are a crucial aspect of most organizational operations. One of the main concerns is business continuity; companies rely on their information systems to run their operations. If a system becomes unavailable, company operations may be impaired or stopped completely. It is necessary to provide a reliable infrastructure for IT operations, in order to minimize any chance of disruption. Information security is also a concern, and for this reason a data center has to offer a secure environment, which minimizes the chances of a security breach. A data center must therefore keep high standards for assuring the integrity and functionality of its hosted computer environment. This is accomplished through redundancy of both fiber optic cables and power, which includes emergency backup power generation. The physical environment of a data center is rigorously controlled. Air conditioning is used to control the temperature and humidity in the data center. It is recommended that a temperature range of 16–24 °C (61–75 °F) and humidity range of 40–55% with a maximum dew point of 15°C as optimal for data center conditions. The heat should be removed from the data centers or the ambient temperature will rise and will result in electronic equipment malfunction. Air conditioning systems help to control humidity by cooling the return space air below the dew point. Too much humidity and water may begin to condense on internal components, which

Raised Floor is also a generic requirement for network and data centers. There are many types of commercially available floors that offer a wide range of structural strength and loading capabilities, depending on component construction and the materials used.

 

The general types of raised floors are:
  • Stringerless Raised Floors
  • Stringered Raised Floors
  • Structural platforms

 

Stringerless Raised Floors:

One non-earthquake type of raised floor generally consists of an array of pedestals that provide the necessary height for routing cables and also serve to support each corner of the floor panels. With this type of floor, there may or may not be provisioning to mechanically fasten the floor panels to the pedestals. This stringerless type of system (having no mechanical attachments between the pedestal heads) provides maximum accessibility to the space under the floor. However, stringerless floors are significantly weaker than stringered raised floors in supporting lateral loads and are not recommended.

 

Stringered Raised Floors:

This type of raised floor generally consists of a vertical array of steel pedestal assemblies (each assembly is made up of a steel base plate, tubular upright, and a head) uniformly spaced on two-foot centers and mechanically fastened to the concrete floor. The steel pedestal head has a stud that is inserted into the pedestal upright and the overall height is adjustable with a leveling nut on the welded stud of the pedestal head.

 

Structural platforms:

One type of structural platform consists of members constructed of steel angles or channels that are welded or bolted together to form an integrated platform for supporting equipment. This design permits equipment to be fastened directly to the platform without the need for toggle bars or supplemental bracing. Structural platforms may or may not contain panels or stringers.

 

Data centers typically have raised flooring made up of 60 cm (2 ft) removable square tiles. The trend is towards 80–100 cm (31–39 in) void to cater for better and uniform air distribution. These provide a plenum for air to circulate below the floor, as part of the air conditioning system, as well as providing space for power cabling.

 

Electrical Power:
Backup power consists of one or more uninterruptible power supplies to prevent single points of failure, all elements of the electrical systems, including backup systems, are typically fully duplicated, and critical servers are connected to both the "A-side" and "B-side" power feeds. This arrangement is often made to achieve redundancy in the systems. Static switches are sometimes used to ensure instantaneous switchover from one supply to the other in the event of a power failure.

Fire Protection:
Fire protection and fire prevention programs are is another essential requirements for a data centre. Smoke detectors are usually installed to provide early warning of a developing fire. This allows investigation, interruption of power, and manual fire suppression using hand held fire extinguishers before the fire grows to a large size. A fire sprinkler system is often provided to control a full-scale fire if it develops. Fire suppression gaseous systems are sometimes installed to suppress a fire earlier than the fire sprinkler system.

Security:

Physical security also plays a large role with data centers. Physical access to the site for most is usually restricted, but the selected personnel with controls including access controls, CCTV surveillance are almost always present. If the data center is large or contains sensitive information on any of the systems within, the use of biometric devices are advisable.

 

About

Company Profile
Hifi Mission
Hifi Vision
Professionalism and Strength
Team work
quality Policy


Services

Web designing & Development
Computer Networking
Voip Phone & PABX
Data Center Solution
CCTV Surveillance System
Time Attendance Installation
Graphic Design
Fleet management

Portfolio

Website Portfolio
Logo Portfolio
Project Gallery
Get A Free Quote

Contact Us

Contact Details
Feedback
Our Location





 


hifilogix.com . Copyright 2008-2011 all rights reserved.